Product Description
Bosch Rexroth R901221174 Hydraulic Direct-Acting Double Solenoid Valve 4WE10E4X/CG24N9DK24L=AN
Next Day Fittings is an authorized Bosch Rexroth distributor. If you have any questions about this product or it's availability, please call us at: 844-323-8752Bosch Rexroth industrial hydraulics solutions are crafted to conquer the most challenging conditions. Bosch Rexroth is synonymous with exceptional performance, steadfast reliability, and precise accuracy in the industrial hydraulics sector. Next Day Fittings takes pride in delivering Bosch Rexroth's top-tier hydraulics technology tailored for the rigorous demands of heavy-duty industries.4WE10E4X/CG24N9DK24L=AN, 4-way 3-positions (4/3) directional control, mech. spring center double solenoid valve, 24Vdc, NBR seals, 4-pin M12 connector with indic. light4-way (4/3) directional control hydraulic direct-acting double solenoid valve (32gpm) with concealed manual override - circuit diagram E - Bosch Rexroth (WE series size 10 / component series 4X) - 4WE 10 E4X/CG24N9DK24L=AN - 24Vdc - 315bar / 4569psi - 4-pin M12 connector with indic. light - NBR seals - Mounting on subplate (Porting pattern according to ISO 4401-05-04-0-05) - IP65 - 4-ports 3-positions - high-power wet-pin solenoid (with detachable coil) - mech. spring center - equivalent to 4WE10E4X/CG24N9DK24L=AN / 4WE10E4XCG24N9DK24LANProduct | Bosch Rexroth Hydraulic direct-acting double solenoid valve |
Model Code | 4WE10E4X/CG24N9DK24L=AN |
Series / Family | WE series - size 10 / component series 4X |
Valve Function | 4/3-way (4 ports / 3 positions), Double solenoid, Monostable |
Max. Flow | 120L/min 32gallons/min |
Max Operating Pressure | 315bar 4569psi |
Hydraulic Fluid Temperature Range | −30°C…+80°C −22°F…+176°F |
Ambient Temperature Range | −30°C…+50°C −22°F…+122°F |
Reset Method | Mechanical Spring |
Manual Override | Flush / Concealed |
Solenoid | High-Power Wet-Pin with Detachable Coil |
Seal Material | NBR |
Connection Type | 4-pin M12 connector with indicator light |
Mounting Mode | Porting pattern according to ISO 4401-05-04-0-05 |
Current Consumption | 2A (nominal hold current) |
Control Voltage (DC) | 24Vdc |
Diagram | circuit diagram E |
Protection Class | IP65 |
Compliant with standard(s) | ISO 4401-05-04-0-05 NFPA T3.5.1 R2-2002 D05 ANSI B93.9 |