Product Description
Balluff BNI006A BNI EIP-508-105-Z015 IO-Link Master
Next Day Fittings is an official Balluff distributor, we can offer our customers the best pricing and factory lead times. Our trained and knowledgeable staff is always ready to help with any aspect of the Balluff product purchasing process. Whether you need assistance from a customer service agent or a product engineering expert, Next Day Fittings is your Balluff partner every step of the way.Protection type IEC 60529 | IP67 when threaded in |
Diagnostic coverage | 0 % |
Functional safety | no |
Mission Time | 20 a |
Approval/Conformity | CE CSA UL 94 ODVA |
Housing material | Zinc, Die casting |
Dimension | 68 x 37.9 x 224 mm |
MTTF (40°C) | 29 a |
Operating voltage Ub | 18...30.2 VDC |
Rated operating voltage Ue DC | 24 V |
Ambient temperature | -5...70°C |
Surface protection | Cu 15 ? Ni 15 ? |
Scope of delivery | Part label (20x) Blind plugs M12 (4x) Ground strap Lock washer Short guide M4x6 screw |
Storage temperature | -25...70°C |
Style | Two-row |
Fastening detail | 2-hole screw mount |
EN 60068-2-6- Vibration | 5...61 Hz, constant amplitude 1 mm 61...500 Hz, constant acceleration 15 g |
Interface | EtherNet/IP |
Actuator supply UA- indicator | LED green |
IO-Link communication indicator | LED green |
Sensor supply US indicator | LED green |
Switching function display | LED yellow |
Contact- surface protection | nickel plated 2 ?m/gold plated 0.4 ?m |
Address range | IPV4 |
Configurable inputs/outputs | yes |
Current sum UA- actuator | 9.0 A |
Current sum US- sensor | 9.0 A |
IO-Link function | Master |
Output current max# | 2 A |
Transfer rate | 10...100 Mbit/s |
Gasket- material | FKM 75 |
Housing shield | yes |
Mounting ground strap | M4 |
Auxiliary interfaces | 8x IO-Link |
Auxiliary interfaces- number | 8x IO-Link |
Digital inputs | 16x PNP, Type 2 |
Digital outputs | 16x PNP |
IO-Link version | 1.1 |